Gaussian AWG
Insertion Loss<3.5dB
Channel Passband ±0.11nm
Center Wavelength Accuracy ±0.05nm
Corephy Athermal AWG DWDM module is using silicon planar technic. It adopts non-hear sensitive structure eliminating the need for chip temperture control.
The 40ch Mux Demux is a high density, low loss and standalone passive optical module that provides excellent solution for infrastructure savings by aggregating up to 48 DWDM channels. All 48 channels are spread over the C-band per ITU-T 100GHz spacing. it can be used to replace the filter-type DWDM. It's perfectly suited to transport PDH, SDH / SONET, ETHERNET services over WDM, CWDM and DWDM.
Applications
PON Networks
DWDM Transmission
Metro Area Networks
Long-haul Networks
Building Blocks for VMUX
Building Blocks for ROADM
Technical Parameter
Parameter | Specifications | Unit | Comment | ||
Min | Max | ||||
Input Channel | 1 | ||||
Output Channel | 16~48 | 16~48 channels available | |||
Channel Spacing | 100 | GHz | |||
Reference Passband | -12.5 | 12.5 | GHz | ||
Wavelength Accuracy | -50 | 50 | pm | Relative to ITU Grid | |
1dB Bandwidth | 0.2(G) | nm | Gaussion Type
| ||
3dB Bandwidth | 0.4(G) | nm | |||
I.L | 3.5 | dB | Worst case in ITU passband | ||
I.L UNI. | 1 | dB | |||
Ripple | 0.7 | dB | Loss variation in ITU passband | ||
PDL | 0.5 | dB | Max. value in ITU passband | ||
Adjacent Crosstalk | 25 | dB | Worst case in ITU passband | ||
Non-Adjacent Crosstalk | 30 | dB | Worst case in ITU passband | ||
Total Crosstalk | 22 | dB | Cumulative crosstalk of all other channels | ||
Return Loss | 40 | dB | |||
Maximum Continuous Optical Power | 300 | mW | Maximum input optical power | ||
Chromatic Dispersion(CD) | -20 | +20 | ps/nm | ||
PMD | 0.5 | ps |
Ordering information
AWG | Spacing | Channel NO. | First Channel | Package | Input connector | Output connector |
AWG | 1=100Ghz 2=200Ghz 5=50Ghz | 32=32 Channel 40=40 Channel 44=44 Channel 48=48 Channel 80=80 Channel 88=88 Channel 96=96 Channel X=Customized | C21 H21 C22 H22 C23 H23 ...... | M=120x70x10mm L=LGX Box R=19″1U Rack X=Others | 00=none LP=LC/UPC LA=LC/APC SP=SC/UPC SA=SC/APC FP=FC/UPC FA=FC/APC X=Customized | 00=none LP=LC/UPC LA=LC/APC SP=SC/UPC SA=SC/APC FP=FC/UPC FA=FC/APC X=Customized |